Welcome to website!
keyword :
Products

Technical Specification

¢ The ideal working pressure: 0.1Mpa -2.0Mpa;

¢ Cold water supply temperature: 10-26;

¢ Hot water supply temperature: 40-85;

¢ Maximum Outlet water temperature: 48±2;

¢ Outlet water temperature stability: when inlet water temperature keeps stable and either of the inlet pressure for cold and hot water varies by 50%, or when inlet water pressure keeps stable(0.3Mpa) and the temperature for the hot water supply increase from 55℃ to 75, the temperature differential from outlet temperature to set temperature shall not exceed 2;

¢ Safety characteristic: If the cold water supply fails, the volume of outlet water collected during the first 5s±0.5s shall be less than 200ml and the temperature of outlet water shall be less than 42, if the water collection greater than 200ml; The volume of the water collected during the second collection period of 30s shall be less than 300ml and the outlet temperature shall not exceed 49. The temperature of the water outlet shall be at 38℃±2℃ after restoration of the cold water supply;

¢ Complies with the following standards: QB2806-2006, EN1111-2008, ASSE1016-2011, AS4032.1-2009.

 

Product Features

¢ Single handle dual control, using a single handle to adjust both temperature and flow, very simple and convenient way for the user to operate;

¢ High pressure resistance both dynamic and static up to 20 bar, provides more reliability and safety;

¢ With fine-tuning special function to help the users to set 38℃ outlet temperature easily under varies conditions;

¢ Cost effective, high quality at low cost.